Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Room humidity transmitter with display 4-20 mA

89,81 € *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to BE, AT, NL (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
M - Measured variable
(M1) % RH
(M2) °C | % RH
Image Changer
2.How many transmitter do you need?
Price calculation
Basic price
89,81 €
M - Measured variable:  
Quantity:  
Configuration is incomplete - please check it!
  • 801110-2022
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Our room humidity transmitter with a current output of 4-20 mA and display can be easily...more
Product information "Room humidity transmitter with display 4-20 mA"

Our room humidity transmitter with a current output of 4-20 mA and display can be easily installed using screws. This device measures the humidity and optionally the temperature. The room humidity transmitter with 4-20 mA display is ideal for the precise measurement of humidity and temperature in indoor areas such as offices, supermarkets and schools. The two-line display shows you either the humidity or the temperature in large format.

Here you can find our downloads for Room humidity transmitter with display 4-20 mA

pdf-download Data sheet Room humidity transmitter with display 4-20 mA
pdf-download Instruction manual Room humidity transmitter with display 4-20 mA
pdf-download Declaration of Conformity Room humidity transmitter with display 4-20 mA
 

Room humidity transmitter - Supply and output

Output 4 - 20 mA
Power consumption < 1,1 VA / 24 V DC
Voltage supply 15 - 36 V DC
Connection type See connection diagrams
 

Room humidity transmitter - General information

Load Ra (Ohm) = (Ub -14 V) / 0,02 A
Sensors Digital humidity sensor, optionally with integrated temperature sensor
 

Room humidity transmitter - Humidity

Measuring element humidity Digital humidity sensor (low hysteresis, high long-term stability)
Measuring range humidity 0 % RH to 100 % RH
Output humidity 4-20 mA
Accuracy humidity ± 2.0 % (20 % RH to 80 % RH) at +25 °C, otherwise ± 3.0 %
Long-term stability ± 1 % / year
 

Room humidity transmitter - Temperature

Measuring element temperature Pt1000 | Class B | DIN EN 60751
Measuring range temperature 0 °C to +50 °C
Output temperature 4 - 20 mA
Accuracy temperature typically ± 0.2 K at +25 °C
 

Room humidity transmitter - Measured variable

Measured variable selectable % RH (Relative humidity),
°C + % RH (Temperature and relative humidity)
 

Room humidity transmitter - Ambient conditions

Storage temperature -25 °C to +50 °C
Operating temperature -5 °C to +55 °C
Permissible air humidity 0 % RH to 95 % RH (without condensation)
 

Room humidity transmitter - Certifications / Standards

Protection class III (according to EN 60 730)
Protection type IP 30 according to EN 60 529
Standards CE conformity
electromagnetic compatibility according to EN 61326
according to EMC Directive 2014/ 30/ EU
 

Room humidity transmitter - Technical drawing

 

Room humidity transmitter - Housing

Material Plastic
Material ABS
Dimensions (L/W/H) (mm) 85 x 85 x 27
Color Pure white (similar to RAL 9010)
Electrical connection 0.14 - 1.5², via screw terminals on circuit board
Display Two lines, lighted
For display of actual temperature and self-diagnostics
(overrange, underrange, probe break, probe short-circuit)
Cut-out Display (B/H) (mm) ca. 36 x 15
 

Room humidity transmitter - Important assembly instructions

For precise measurement of room temperature and humidity, it is crucial to take into account both the temperature dynamics and the humidity dynamics in the room. Air circulation should only take place through the openings in the housing cover. Therefore, the transmitter should be installed away from objects or obstacles that could block air movement. Also avoid uncontrolled air currents (draughts) by installing the transmitter near doors or windows. The transmitter should also not be installed on the colder outside wall to prevent measurement inaccuracies.
The device should only be used in pollutant-free, non-condensing air (< 95 % RH).
 

Room humidity transmitter - Delivery

Delivery Transmitter, Operating instructions
Packing individually packed in cardboard box
Properties
Output: 4-20 mA
Gehäuse: Gehäuse mit Display
Input: digitaler Feuchtesensor
Messgröße: °C + % RH
Schutzart: IP 30 nach EN 60 529
Type: Raum-Feuchtetransmitter
Related links to "Room humidity transmitter with display 4-20 mA"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Room humidity transmitter with display 4-20 mA"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Raum-Feuchtetransmitter 4-20 mA Vorderansicht 2 Room humidity transmitter 4-20 mA
61,24 € *
Order number: 801110-1022
Add to shopping cart
Raum-Feuchtetransmitter Design 4-20 mA Vorderansicht 2 Room humidity transmitter design 4-20 mA
59,09 € *
Order number: 801110-6022
Add to shopping cart
Raum-Feuchtetransmitter mit Display 0-10 V Vorderansicht 2 Room humidity transmitter with display 0-10 V
89,81 € *
Order number: 801110-2023
Add to shopping cart